HA Measuring by JINGYAO INSTRUMENT equips labs to build, test, fill and pack e-cigs, plus car, climate, sports, battery and furniture tests and charging aging cabinets.
The Electronic Cigarette Airtightness Testing Machine is a professional leakage detection system designed for high-precision quality control in the e-cigarette manufacturing industry. Using a sensitive pressure-decay method, the system identifies defects in e-cigarette cartridges by monitoring minute internal pressure variations.
The equipment features a modular design available in 1- to 6-channel configurations, making it suitable for both laboratory testing and high-speed production lines. With a 4.3-inch touch-screen interface, operators can easily manage testing parameters to ensure stable, accurate, and repeatable results.
Precision Detection: Employs advanced pressure sensors with ±0.2% accuracy and 1 Pa resolution for reliable leak identification.
High Efficiency: Optimized cycle times (Inflate / Balance / Detection / Exhaust) enable rapid testing without compromising accuracy.
User-Friendly Interface: Features a 4.3-inch intuitive touch screen for straightforward operation and parameter management.
Scalable Configuration: Supports multiple test channels to match your production requirements.
Parameter Memory: Stores up to 2 sets of product setting parameters for quick switching between different cartridge models.
Device Type |
One channel |
Two channels |
Four channels |
Six channels |
|
Type |
Positive pressure type |
Positive pressure type |
Positive pressure type |
Positive pressure type |
|
Detect pressure range |
0 to +101 kPa |
0 to +101 kPa |
0 to +101 kPa |
0 to +101 kPa |
|
Pressure sensor |
Range: 0 to 101 kPa |
Range: 0 to 101 kPa |
Range: 0 to 101 kPa |
Range: 0 to 101 kPa |
|
Accuracy: ±0.2% |
Accuracy: ±0.2% |
Accuracy: ±0.2% |
Accuracy: ±0.2% |
||
Resolution: 1 Pa |
Resolution: 1 Pa |
Resolution: 1 Pa |
Resolution: 1 Pa |
||
Number of channels |
Save up to 2 sets of product setting parameters |
Save up to 2 sets of product setting parameters |
Save up to 2 sets of product setting parameters |
Save up to 2 sets of product setting parameters |
|
I/O interface |
2 input signals / 2 output signals |
2 input signals / 2 output signals |
2 input signals / 2 output signals |
2 input signals / 2 output signals |
|
Time |
Travel itinerary name |
Minimum value (S) |
Minimum value (S) |
Minimum value (S) |
Minimum value (S) |
Inflate |
0.2 |
0.2 |
0.2 |
0.2 |
|
Balance |
0.1 |
0.1 |
0.1 |
0.1 |
|
Detection |
0.1 |
0.1 |
0.1 |
0.1 |
|
Exhaust |
0.2 |
0.2 |
0.2 |
0.2 |
|
Display |
4.3-inch touch screen display |
4.3-inch touch screen display |
4.3-inch touch screen display |
4.3-inch touch screen display |
|
Power supply |
AC 220 V, 50 Hz, approx. 100 W |
AC 220 V, 50 Hz, approx. 100 W |
AC 220 V, 50 Hz, approx. 100 W |
AC 220 V, 50 Hz, approx. 100 W |
|
Test pressure source |
Use a clean air source with high flow rate and pressure, and connect it to a stable air pressure source adjusted by a pressure regulating valve. |
Use a clean air source with high flow rate and pressure, and connect it to a stable air pressure source adjusted by a pressure regulating valve. |
Use a clean air source with high flow rate and pressure, and connect it to a stable air pressure source adjusted by a pressure regulating valve. |
Use a clean air source with high flow rate and pressure, and connect it to a stable air pressure source adjusted by a pressure regulating valve. |
|
Environmental temperature and humidity |
Temperature: 5 to 40 ℃; Humidity: ≤ 80% RH; No condensation |
Temperature: 5 to 40 ℃; Humidity: ≤ 80% RH; No condensation |
Temperature: 5 to 40 ℃; Humidity: ≤ 80% RH; No condensation |
Temperature: 5 to 40 ℃; Humidity: ≤ 80% RH; No condensation |
|