An electric thermal drum dryer uses heating elements to generate heat and circulates air evenly inside the drum with a circulating fan for rapid, uniform drying. It is used in scientific research, industry, medical and other applications for drying, baking, sterilization, and temperature testing.
An electric thermal drum dryer uses heating elements to generate heat and circulates air evenly inside the drum with a circulating fan for rapid, uniform drying. It is used in scientific research, industry, medical and other applications for drying, baking, sterilization, and temperature testing.
An electric thermal drum dryer is a heating chamber designed to generate heat using heating elements and to circulate air evenly throughout the drying compartment via a circulating fan. This ensures rapid, uniform drying. It is widely used in scientific research, industry, medical applications, and other fields for drying, baking, sterilization, and temperature testing.

Category Keywords
Type of equipment Electrothermal drum dryer, Electrothermal constant-temperature drum dryer (precision dryer), High-temperature oven
Core functions Drying, baking, sterilization, temperature testing, heat treatment, dehydration drying
Technical features Hot-air circulation, intelligent temperature control, timing function, temperature limit alarm, PID self-tuning
Material features Stainless-steel inner lid, spray-treated steel enclosure, double-glazed glass observation window
Safety features Independent temperature limit alarm, fan stop protection, over-temperature protection
III. Main technical parameters
3.1 General technical parameters
form
Parameter item Specifications range
Temperature range RT + 10°C ~ 200°C / 300°C (some models: up to 500°C, 800°C, 1200°C)
Temperature fluctuation ± 1°C (precision model: up to ± 0.1°C) [Reference value]
Temperature uniformity ± 2°C [Reference value]
Temperature resolution 0.1°C [Reference value]
Timing range 1 ~ 9999 minutes
Supply voltage AC 220V / 50Hz (380V for some high-power models)
Heating power 2kW ~ 4.5kW (depending on model)
Two drum carriers (standard); each carrier supports approximately 15 kg
3.2 Common model specifications (units: mm)
form
Model Internal size External size Temperature range
DHG-9030A 340×325×325 625×510×490 RT+10°C~250°C
DHG-9070AD 450×400×450 740×580×630 RT+10°C~250°C
DHG-9140AD 550×450×550 830×650×730 RT+10°C~250°C
DHG-9240AD 600×550×650 880×770×930 RT+10°C~250°C
KLG-9020A 300×300×300 410×400×640 RT+10°C~200°C
KLG-9070A 410×410×410 525×520×750 RT+10°C~200°C
> Data Sources:
IV. Structures and materials
form
Place Material / Design
Inner tank Mirror stainless steel (SUS304) argon-arc welding, or zinc plating
Enclosure Spray-treated high-quality steel plate, rust-proof and aesthetically finished
Observation windows Large-area double glazing
Insulation layer Ultrafine glass fiber filling
Air turbine systems Imported original high-temperature turbines + optimized wind-tunnel design
Control system Smart LCD program controller (optional, 10–30 programming steps)
Safety protection Independent temperature limit alarm system, fan stop switch, over-temperature protection
V. Application areas
form
Industry Application scenario Typical temperature
Scientific / laboratory Sample drying, sterilization, temperature testing 60°C – 200°C
Electronics / semiconductors Component drying, aging testing, moisture-proof storage 50°C – 150°C
Chemical / new materials Raw material drying, curing, heat treatment 80°C – 300°C
Food / medicine Dehydrated drying, medicinal drying, food processing 40°C – 120°C
Hardware / electroplating Workpiece drying, oil treatment, surface treatment 100°C – 250°C
Biological experiments DNA sample drying, dish sterilization 60°C – 120°C
> Data Sources:
VI. Operational highlights and precautions
6.1 Pre-use preparation
Check that the power cable is intact and that the grounding is reliable.
Ensure the chamber interior and exterior are clean and that there is no debris or impurities around the heating element.
Check that all seals are intact and that the door can be fully closed.
Place the equipment on a level, well-ventilated surface, away from flammable and explosive materials.
6.2 Standard operating procedures
Turn on the power and switch on the power switch.
Set the operating temperature (the initial temperature should not be too high).
Turn on the drum switch to promote air circulation.
Load the material (spread evenly to prevent over-thick accumulation).
Monitor operating status through the observation window during operation.
When drying is complete, turn off the heating and wait until the temperature drops below 60°C before removing the materials.
6.3 ⚠️Important safety warnings
form
Prohibited items Explanation
Flammable and explosive items must not be placed in the drying chamber for heating to avoid the risk of explosion.
Volatile chemicals are strictly prohibited from being placed inside.
Excessive use is prohibited. Do not set a temperature higher than the device’s rated maximum temperature.
Unattended operation is prohibited. Regular checks (patrols) should be carried out during operation.
Do not open the door at high temperatures. Avoid opening the door during high-temperature operation.
VII. Selection recommendations
Select the temperature range based on the material characteristics: thermally sensitive materials should use a low-temperature type (< 100°C); for ordinary materials, select a 200°C class.
Select the chamber volume according to the load: consider the shape and size of the items, as well as the number of drum carriers.
Select the controller based on precision requirements: a display-type controller for general experiments; an intelligent program controller for precision experiments.
Select materials based on the operating environment: for corrosive environments, stainless-steel enclosures are recommended.
Allow sufficient clearance for heat dissipation: keep at least 30 cm from the wall on the surrounding sides and the rear of the chamber.
VIII. Maintenance and upkeep
Clean the interior after each use until the chamber is completely cooled.
Regularly inspect the heating components and the turbine operation.
Worn or damaged seal strips should be replaced in a timely manner.
For extended periods of non-use, disconnect power, allow the chamber to dry, and periodically energize the unit to dehumidify.