PUSH Electrical PS-Vlfm 0.1Hz 80kV Ultra-Low Frequency High Voltage Generator

This unit uses modern digital frequency conversion technology with microcomputer control. Voltage boost and reduction, voltage measurement, and protection are fully automated, and manual intervention is available during automatic boosting. Fully electronic for compact, lightweight operation, it features a large LCD display with clear, intuitive operation and a built-in printer for outputting test reports.


This unit uses modern digital frequency conversion technology with microcomputer control. Voltage boost and reduction, voltage measurement, and protection are fully automated, and manual intervention is available during automatic boosting. Fully electronic for compact, lightweight operation, it features a large LCD display with clear, intuitive operation and a built-in printer for outputting test reports.

Product Selling Points

 

  1. Current and voltage are measured via sampling from the high-voltage side, ensuring the data is accurate and reliable.
  2. Overvoltage protection: If the output exceeds the preset voltage limit, the unit shuts down to protect the system. The response time is less than 20 ms.
  3. Overcurrent protection: The design provides dual protection for both high- and low-voltage sides. On the high-voltage side, precise shutdown protection is performed according to the preset value. On the low-voltage side, if the current exceeds the rated current, shutdown protection is triggered. The response time is less than 20 ms.
  4. The high-voltage output protection resistor is built into the booster, so there is no need to connect an external protection resistor.
  5. With the high- and low-voltage closed-loop negative feedback control circuit, the output has no capacitance rise effect.

 

Product Parameters

 

Model

Rated Voltage

Load Capacity

Power Fuse

Weight

Application

80 kV ultra low frequency

80 kV

(Peak)

0.1 Hz, ≤ 0.5 µF

25 A

Controller: 6 kg

Booster I: 30 kg

Booster II: 50 kg

For cables and generators up to 35 kV

0.05 Hz, ≤ 1.0 µF

0.02 Hz, ≤ 2.5 µF

0.01 Hz, ≤ 5.0 µF

Use alone
No. 1 booster

30 kV

(Peak)

0.1 Hz, ≤ 1.1 µF

For cables and generators up to 10 kV

0.05 Hz, ≤ 2.2 µF

0.02 Hz, ≤ 5.5 µF

0.01 Hz, ≤ 11.0 µF