The PS-9001 gas chromatograph can be configured with a range of detectors to match your analytical needs across different fields. Its front inlet design supports multiple sampling methods, including headspace and thermal desorption sampling, for efficient analysis of a wide variety of samples.
The PS-9001 gas chromatograph can be configured with a range of detectors to match your analytical needs across different fields. Its front inlet design supports multiple sampling methods, including headspace and thermal desorption sampling, for efficient analysis of a wide variety of samples.

1. Wide variety of detector modules
The system can be equipped with a range of detectors to meet the analytical requirements of different applications. The advanced injection port design supports multiple sampling methods, such as headspace sampling and thermal analysis sampling, enabling efficient analysis of a wide range of sample types.
2. Powerful detection expansion capability
The detector and associated control components use a modular, unitized design. The extended control mode system is plug-and-play.
3. Ultra-efficient rear door design
The intelligent rear door temperature control system ensures stable column chamber temperature across all zones. Cooling is fast and supports near-room-temperature operation.
The unit features an enhanced self-diagnosis function at start-up, with intuitive fault display. It also includes power-failure data protection, automatic screen saver, and anti-power-interference capability.
- Temperature control area: 8-way independent temperature control system, with automatic temperature protection. Independent small-column oven heating zones can be configured.
- Screen size: 7-inch industrial color LCD screen
- Language: Chinese/English dual operating system
- Temperature range (column box, gasification chamber, detector): room temperature +5°C to 450°C
- Temperature setting accuracy: 0.1°C
- Maximum heating rate: 80°C/min
- Cooling rate: from 350°C to 50°C < 5 min
- Intelligent rear door: stepless adjustment of air inlet and outlet flow
- Program heating sequence: 16 steps (expandable)
- Maximum run time: 999.99 min
- Injection mode: capillary column split/splitless injection (with diaphragm purge function), packed column injection, valve injection, gas/liquid automatic sampling system, etc.
- Injection valve: Supports multiple automatic control valves for automated sequence operation
- Number of detectors: 4
- Detector types: FID, TCD, ECD, FPD, NPD, PDHID, PED, etc.
Hydrogen Flame Detector (FID)
Minimum detection limit: ≤3.0 × 10-12 g/s (n-hexadecane/isooctane: reference/typical value)
Dynamic linear range: ≥107
Includes fire detection and automatic re-ignition function
Wide-range logarithmic amplifier circuit to improve the linear range
Thermal Conductivity Detector (TCD)
Sensitivity: ≥10000 mV·mL/mg (benzene/toluene: reference/typical value)
Dynamic linear range: ≥105
Micro-cavity design with low dead volume for high sensitivity, with gas cut-off protection function
Flame Photometric Detector (FPD)
Minimum detection limit: S ≤ 2 × 10-11 g/s (methyl parathion: reference/typical value)
P ≤ 1 × 10-12 g/s (methyl parathion: reference/typical value)
Dynamic linear range: S ≥ 103; P ≥ 104
Fully passivated internal flow path, with no cold spot for organic phosphorus