PUSH Electrical PS-RG03 Capacitance Inductance Tester

Designed to address measurement requirements for high-voltage shunt capacitor banks in substations, this instrument is developed in accordance with GB3983.2-1989 “High-voltage shunt capacitors,” DL/T840-2003 “Technical conditions for the use of high-voltage shunt capacitors,” and JB5346-1998 “Series Reactors.” It is mainly used to measure high-voltage parallel capacitor banks and reactors for reactive power compensation devices.


Designed to address measurement requirements for high-voltage shunt capacitor banks in substations, this instrument is developed in accordance with GB3983.2-1989 “High-voltage shunt capacitors,” DL/T840-2003 “Technical conditions for the use of high-voltage shunt capacitors,” and JB5346-1998 “Series Reactors.” It is mainly used to measure high-voltage parallel capacitor banks and reactors for reactive power compensation devices.

Product Selling Points

 

  1. 1. This instrument measures the capacitance of a single capacitor within a group of parallel capacitors without disconnecting the wiring. Both single-phase and three-phase capacitance configurations can be measured.
  2. 2. During measurement, the instrument can display the measured capacitance or inductance value. It can also display additional measured parameters, including voltage, current, power, frequency, impedance, phase angle, and other data.
  3. 3. The instrument features a 7.0-inch 1024×600 high-definition touchscreen for clear daytime and nighttime viewing. The Chinese on-screen menu prompts make operation straightforward.
  4. 4. Built-in large-capacity non-volatile memory stores up to 200 sets of measurement data. An integrated U-disk interface allows storage of measurement data from any group (subject to the U-disk capacity).
  5. 5. The instrument includes a high-precision real-time clock with date and time calibration.
  6. 6. A high-speed micro-thermal printer is provided to print measurement results and historical data.

 

Product Parameters

 

Test Voltage

AC 100 V ±10%, 50 Hz

AC 40 V ±10%, 50 Hz

AC 10 V ±10%, 50 Hz

AC 1 V ±10%, 50 Hz

Measuring Range and Accuracy

Measurable Capacitance Range

0.1 µF~6000 µF ±(reading 1% + 0.01 µF)

Measurable Inductance Range

50 µH~20 H ±(reading 3% + 0.05 µH)

Measurable Current Range

5 mA~2 A ±(3% of reading + 0.05 mA)

Measurable Resistance Range

20 mΩ~20 kΩ ±(reading 3% + 0.1 mΩ)

Dimensions

365 mm × 285 mm × 170 mm

Ambient Temperature

-20℃~40℃

Ambient Humidity

≤85% RH

Operating Power

AC 220 V ±10%, 50 ±1 Hz

 

Video